show power supply status cisco 3560

Switch# show stack-power, power stack name: Powerstack-1 Stack mode: Power sharing strict, stack topology: Ring Switch 1: Power budget: 223 Low pdf er ist wieder da port priority value: 21 High port priority value: 12 Switch priority value: 3 Port 1 status: Connected crack xbox 360 played games Port 2 status: Connected Neighbor on port.
Temperature readings: NPE Inlet measured at 31C/87F NPE Outlet measured at 36C/96F.
Last, the lost redundancy state is repeated every 60 seconds.First, the power supply is seen as no longer responded.Cisco Catalyst 2960 running Cisco IOS Software, C2960 Software (C2960-lanbasek9-M Version.2(37)SE1, release software (fc1).Switch# conf t, enter configuration commands, one per line.This is normally not a problem because most devices do not run at full power and the chances of multiple powered devices in the stack requiring maximum power at the same time is small.In the current Cisco Catalyst 3750-X switch pair I have sitting on my desk, I have taken advantage of the new StackPower feature.Power stack configuration mode: default Set a command to its defaults exit Exit from power stack configuration mode Power stack mode no Negate a command or set its defaults.This means that you no longer have to have redundant power supplies in every switch.Seen from the output above, the default mode is power sharing strict. .Another benefit is that you can replace a power supply in a switch without ever having to take the switch offline; assuming youve got the spare power budget available, StackPower will take care of keeping your switch powered while you replace the defective supply, even.



Just a quick one today.
Lets go for the gold.
Links Managing Catalyst 3750-X StackPower.So whats delete temp files windows 7 cmd a power supply failure look like?That information is nestled snugly in the show environment command.Strict Strict mode cr Switch(config-stackpower mode redundant strict, switch(config-stackpower z Switch# show stack-power, power stack name: Powerstack-1 Stack mode: Redundant strict Stack topology: Ring Switch 1: Power budget: 223 Low port priority value: 21 High port priority value: 12 Switch priority value: 3 Port.Envm stats saved 3 time(s) since reload.Note that I have both StackPower cables connected from switch 1 to switch.You can choose between power-sharing (one big happy power supply) and redundant (the largest power supply is kept as a reserve).Your alternative is redundant mode, which is easy enough to set.With my stack-power configured in redundant strict mode (meaning one supply is a spare, and potential power requirement cannot exceed power budget I am going to disconnect one of the supplies on the switch I am consoled into, which happens to be switch.




Sitemap